The best Anti-Ferritin, Recombinant Human NUDT1 Protein Heavy Polypeptide
(FTH)-Rabbit polyclonal Antibody products,
quick delivery, high quality.

Back to: Our Providers / bioma / Rat A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) ELISA Kit, 96 well plate

Size

96T

Price

874.00

Catalog

EKU02056

Quick and safe buy process

Assay principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Description

A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals. A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.

ELISA's stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Precision of the test

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV

ELISA's specificity

This assay has high sensitivity and excellent specificity for detection of A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1). No significant cross-reactivity or interference between A Disintegrin And Metalloproteinase With Thrombospondin 1 (ADAMTS1) and analogues was observed.

About

Rats are used to make rat monoclonal anti mouse antibodies. There are less rat- than mouse clones however. Rats genes from rodents of the genus Rattus norvegicus are often studied in vivo as a model of human genes in Sprague-Dawley or Wistar rats.

Warnings

The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

Storage recommendation

-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

ELISA's cross-reactivity

This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.

Properties

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays

QC

The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Samples to be analyzed

Serum, plasma, tissue homogenates and other biological fluids.

Test

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Gene name

A Disintegrin And Metalloproteinase With Thrombospondin 1

Notes

For research use only. Not for diagnostic procedures.

Protocol

Please see ELISA's datasheet, otherwise contact us

Alternate protein number

Please refer to SwissProt

Verified reactivity

Rattus norvegicus (Rat)

Gene number

Please refer to GenBank

Estimated production time

7-11 business days

Latin name

Rattus norvegicus

Detection limits

78.12-5000 pg/mL

Research main area

Tumor immunity;

Alternate gene name

C3-C5; METH1

ELISA detection

Colorimetric

Sensitivity limit

30,5 pg/mL

Shipping requirements

Blue ice

Assay class

Sandwich

Use for

8 months

Assay duration

3 hours

Protein number

Q9WUQ1

Verified applications

ELISA

Simply order proccess

Just click and buy.